尺寸計算
風管尺寸=風量/風速
風量=房間(jian)面(mian)積*房間(jian)高*換氣次數
例子:風(feng)量4萬,風(feng)速9m/s,
得(de)風管尺寸(cun)=40000/9/3600=1.23平方
1.23=1.5*0.82
所以 風管尺(chi)寸(cun)為1500*800 。
管道直徑設計計算步驟:
1、繪制通風(feng)或空調系(xi)統軸測圖(tu),對各(ge)管段進行(xing)編號,標注(zhu)長度和風(feng)量。管段長度一般按兩管件(jian)中(zhong)心線長度計算,不扣(kou)除管件(jian)(如(ru)三通,彎頭)本身(shen)的長度。
2、確定合(he)理的空氣速流
風(feng)管(guan)(guan)內的(de)空(kong)氣流速(su)對(dui)通風(feng)、空(kong)調系(xi)(xi)統(tong)的(de)經(jing)濟型有(you)較大(da)的(de)影響。流速(su)高,風(feng)管(guan)(guan)斷面(mian)小(xiao),材料耗(hao)用(yong)(yong)少(shao),建造費(fei)用(yong)(yong)小(xiao);但(dan)是(shi)系(xi)(xi)統(tong)的(de)阻(zu)力大(da),動(dong)力消(xiao)耗(hao)增(zeng)(zeng)大(da),運用(yong)(yong)費(fei)用(yong)(yong)增(zeng)(zeng)加。對(dui)除塵系(xi)(xi)統(tong)會(hui)增(zeng)(zeng)加設備(bei)和(he)管(guan)(guan)道的(de)磨損,對(dui)空(kong)調系(xi)(xi)統(tong)會(hui)增(zeng)(zeng)加噪聲。流速(su)低,阻(zu)力小(xiao),動(dong)力消(xiao)耗(hao)少(shao);但(dan)是(shi)風(feng)管(guan)(guan)斷面(mian)大(da),材料和(he)建造費(fei)用(yong)(yong)大(da),風(feng)管(guan)(guan)占用(yong)(yong)的(de)空(kong)間也增(zeng)(zeng)大(da)。對(dui)除塵系(xi)(xi)統(tong)流速(su)過低會(hui)使粉塵沉積堵塞管(guan)(guan)道。