戶外不銹鋼風管
尺寸計算
風管尺寸=風量/風速
風量=房間(jian)面積*房間(jian)高(gao)*換氣次數
例子:風量4萬,風速9m/s,
得風管尺寸(cun)=40000/9/3600=1.23平方
1.23=1.5*0.82
所以(yi) 風管尺寸(cun)為(wei)1500*800 。
管道直徑設計計算步驟:
1、繪制通(tong)風(feng)或空調系(xi)統軸(zhou)測圖,對(dui)各管(guan)段進(jin)行(xing)編號,標(biao)注長度(du)(du)和風(feng)量。管(guan)段長度(du)(du)一般按兩管(guan)件中心線長度(du)(du)計算,不扣除管(guan)件(如三通(tong),彎頭)本身的長度(du)(du)。
2、確定(ding)合(he)理的空(kong)氣速流
風(feng)(feng)管(guan)(guan)(guan)(guan)內的空氣(qi)流(liu)(liu)速(su)對(dui)(dui)通(tong)風(feng)(feng)、空調系(xi)(xi)統(tong)(tong)的經濟型(xing)有(you)較大(da)(da)(da)(da)的影響。流(liu)(liu)速(su)高,風(feng)(feng)管(guan)(guan)(guan)(guan)斷面小(xiao),材料耗用(yong)少,建(jian)造費(fei)用(yong)小(xiao);但(dan)是系(xi)(xi)統(tong)(tong)的阻(zu)力(li)(li)大(da)(da)(da)(da),動力(li)(li)消耗增大(da)(da)(da)(da),運用(yong)費(fei)用(yong)增加。對(dui)(dui)除塵(chen)(chen)(chen)系(xi)(xi)統(tong)(tong)會(hui)(hui)增加設備和管(guan)(guan)(guan)(guan)道的磨損,對(dui)(dui)空調系(xi)(xi)統(tong)(tong)會(hui)(hui)增加噪聲。流(liu)(liu)速(su)低,阻(zu)力(li)(li)小(xiao),動力(li)(li)消耗少;但(dan)是風(feng)(feng)管(guan)(guan)(guan)(guan)斷面大(da)(da)(da)(da),材料和建(jian)造費(fei)用(yong)大(da)(da)(da)(da),風(feng)(feng)管(guan)(guan)(guan)(guan)占(zhan)用(yong)的空間也(ye)增大(da)(da)(da)(da)。對(dui)(dui)除塵(chen)(chen)(chen)系(xi)(xi)統(tong)(tong)流(liu)(liu)速(su)過(guo)低會(hui)(hui)使粉塵(chen)(chen)(chen)沉積堵(du)塞管(guan)(guan)(guan)(guan)道。